Airflow
Static pressure, filter condition, blower wheel cleanliness, evaporator coil condition and return-air adequacy.
A measured inspection, not a two-minute glance at the filter.
A heating and cooling system is the hardest-working appliance in the house and the only one most people never service. A dirty coil or a weak capacitor does not announce itself; it simply raises the electricity bill and shortens the compressor's life until something fails at the worst possible moment.
Cooling tune-ups in spring, heating tune-ups in autumn. Call (803) 276-9685 and ask for the seasonal special.
It is not a two-minute glance at the filter. It is a measured inspection with airflow, electrical and refrigerant checks and a written record.
Static pressure, filter condition, blower wheel cleanliness, evaporator coil condition and return-air adequacy.
Suction and discharge pressures, superheat and subcooling, and a leak inspection on accessible joints.
Capacitor microfarad values, contactor pitting, amp draw on the compressor and both fan motors, and control wiring.
Drain pan condition, trap, slope, float switch operation and evidence of overflow.
Coil cleaning, fan blade balance, pad level, disconnect condition and clearance from vegetation.
Thermostat calibration, schedule review and cycling behaviour under load.
Flame quality, gas pressure, burner cleanliness and flue draft — the checks that keep a furnace safe.
Visual inspection for cracks and corrosion. This is a carbon-monoxide safety item, not a maintenance nicety.
Hot-surface igniter, flame sensor, pressure switch, limit switches and rollout protection.
Defrost cycle timing, reversing valve operation, auxiliary and emergency heat staging, and outdoor sensor.
Motor amp draw, wheel balance, belt condition where applicable and filter replacement.
Humidifier operation, water panel condition, solenoid and bypass damper for winter comfort.
Change or clean the filter. A blocked filter is the most common cause of frozen coils and short compressor life. In our climate, monthly is realistic during peak cooling season for a 1-inch filter.
Keep the outdoor unit clear. Two feet of clearance all round, and keep grass clippings and dryer lint away from the coil.
Check the drain. Pour a cup of water into the drain pan and confirm it runs away freely. A clogged drain is the leading cause of summer water damage.
Keep registers open. Closing vents in unused rooms does not save energy; it raises static pressure and can damage the compressor.
Most manufacturers require documented annual maintenance to honour parts warranties. Keep your service records — we keep copies as well, so a claim is never a scramble.
Call Wilson's Refrigeration and A/C Service and talk to the people who will actually do the work. Same-day service is available on most calls.